title = "Decoding the FAST Protocol"
|
|
|
|
date = 2022-01-10
|
|
|
|
updated = 2022-01-13
|
|
|
|
|
|
|
|
[taxonomies]
|
|
|
|
tags = ["finance", "binary", "protocol", "fix", "fast"]
|
|
|
|
+++
|
|
|
|
|
|
|
|
Recently I have to work with a FAST (FIX Adapted for Streaming) and because the
|
|
|
|
documentation is scattered around, I decided to put the things I discovered in a
|
|
|
|
single place for (my own) future reference.
|
|
|
|
|
|
|
|
<!-- more -->
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
Because this is based on my personal experience and I had contact with a single
|
|
|
|
instance of this so far, there are some things that are incomplete and/or
|
|
|
|
wrong. I'll keep updating this post as I figure out new things.
|
|
|
|
|
|
|
|
The changelog is in the end of the post.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
# What is FAST
|
|
|
|
|
|
|
|
[FAST](https://en.wikipedia.org/wiki/FAST_protocol) is, basically, a compression
|
|
|
|
method for the FIX protocol.
|
|
|
|
|
|
|
|
# And What is FIX?
|
|
|
|
|
|
|
|
[FIX](https://en.wikipedia.org/wiki/Financial_Information_eXchange) is a
|
|
|
|
protocol created for financial institutions to exchange information. Although
|
|
|
|
there is nothing "financially" related to it -- you could use the protocol for
|
|
|
|
anything, basically -- most financial companies use it.
|
|
|
|
|
|
|
|
FIX is a very simple protocol: You have pairs of "field ID" and "value"
|
|
|
|
separated by a "`=`" (equal sign) and the pairs are separated by the ASCII char
|
|
|
|
with code 1 (which is represented by `^A` in some editors). Some field IDs are
|
|
|
|
defined by the protocol (there is a whole list
|
|
|
|
[here](https://www.inforeachinc.com/fix-dictionary/index.html)) but each
|
|
|
|
exchange can create their own IDs.
|
|
|
|
|
|
|
|
For example, if you have the field MsgType (ID 35) with value "`y`" and the
|
|
|
|
field Security ID (ID 48) with value "`123456`", the message received would be
|
|
|
|
|
|
|
|
```
|
|
|
|
35=y^A48=123456
|
|
|
|
```
|
|
|
|
|
|
|
|
# And Back to FAST
|
|
|
|
|
|
|
|
One of the things FAST is designed for is removing duplicate and/or constant
|
|
|
|
content. For example, MsgType (ID 35) identifies that the message is
|
|
|
|
"SecurityList" (symbol list), which contains information about all the symbols
|
|
|
|
(the their security IDs) available in the exchange. Because the exchange is the
|
|
|
|
same in all the symbols, FAST allows defining the fields related to it (Source,
|
|
|
|
field ID 22, and Exchange, field ID 207) to constant values, so they don't need
|
|
|
|
to be transmitted and, when decoding FAST back to FIX, the decoder simply add
|
|
|
|
the constant value.
|
|
|
|
|
|
|
|
To know which fields are constant and which are not (and some other information),
|
|
|
|
the protocol defines a template, which have a well defined schema, to report
|
|
|
|
that information.
|
|
|
|
|
|
|
|
# The Template
|
|
|
|
|
|
|
|
The template is a XML file which describes the fields, their types, names, IDs
|
|
|
|
and operators. The protocol itself doesn't provide any default way to actually
|
|
|
|
receive that field, and thus is left for the exchange to find their way.
|
|
|
|
|
|
|
|
Note that the template describe the field IDs and their types, and the incoming
|
|
|
|
data have only the values. If we use the FIX description above, the template
|
|
|
|
defines the left side of the pair, while the incoming data have have only the
|
|
|
|
right side.
|
|
|
|
|
|
|
|
## Field Types
|
|
|
|
|
|
|
|
The protocol have a few field types: Unsigned Ints of 32 and 64 bits, Signed
|
|
|
|
Ints of 32 and 64 bits, ASCII strings, UTF-8 strings, sequences, decimals and a
|
|
|
|
special type called "Presence Map".
|
|
|
|
|
|
|
|
One thing to note is that all fields use a "stop bit" format. This is quite
|
|
|
|
similar to UTF8, although UTF8 uses a "continuation bit" instead of "stop bit",
|
|
|
|
but the process of reading is the same:
|
|
|
|
|
|
|
|
- Read a byte;
|
|
|
|
- Does it have the high order by set to 0?
|
|
|
|
- Yes: Keep reading;
|
|
|
|
- No: Stop reading the field value.
|
|
|
|
|
|
|
|
I'll show some examples later in this post.
|
|
|
|
|
|
|
|
## Field definitions
|
|
|
|
|
|
|
|
The template defines the fields with their type, name (optional), ID, a
|
|
|
|
presence indicator and an operator (optional).
|
|
|
|
|
|
|
|
For example, to describe an unsigned int of 32 bits, named "MsgType" with ID
|
|
|
|
"35", it would be described in the template as
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<uInt32 name="MsgType" id="35"/>
|
|
|
|
```
|
|
|
|
|
|
|
|
Because there is no indication of presence, it is assumed that the field is
|
|
|
|
"mandatory" and should always have a value. On the other hand, if the field
|
|
|
|
definition was something like
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<int32 name="ImpliedMarketIndicator" id="1144" presence="optional"/>
|
|
|
|
```
|
|
|
|
|
|
|
|
... then the field may not not have a value. This is also referred as "nullable"
|
|
|
|
field.
|
|
|
|
|
|
|
|
## Optional and Mandatory Fields
|
|
|
|
|
|
|
|
The difference between optional and mandatory fields is that mandatory fields
|
|
|
|
*always* have a value, even if 0. Optional fields, on the other hand, can be
|
|
|
|
null and have no value at all.
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
I have the impression that this is done if the exchange wants to mark a field
|
|
|
|
as "do not appear in the FIX version"; so even if the field have a definition,
|
|
|
|
the resulting FIX version would not have the field.
|
|
|
|
|
|
|
|
So it is more of a "backwards compatibility" than anything else.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
## Types
|
|
|
|
|
|
|
|
### Types: Ints
|
|
|
|
|
|
|
|
To read an Int, the decoder would pick the 7 low order bits (everything except
|
|
|
|
the high order one) and move them to the resulting variable. If the stop bit is
|
|
|
|
there, the read is complete; if it is not, the result should be shifted by 7
|
|
|
|
bits and add the 7 bits from the next byte and so on, till you find a byte with
|
|
|
|
the stop bit set.
|
|
|
|
|
|
|
|
The 32 and 64 bits only define the maximum value of the field and should not
|
|
|
|
necessarily be used as "number of bits to be read" -- because of the stop bit.
|
|
|
|
If the value exceeds 32 or 64 bits, that is considered an error and the
|
|
|
|
processing should be aborted.
|
|
|
|
|
|
|
|
Signed Int work exactly the same, but as 2's complement.
|
|
|
|
|
|
|
|
For example, if incoming data have the following bytes (in binary, to make it
|
|
|
|
easier to read; also, I added a single underscore between each 4 values, also
|
|
|
|
to make it easier to read):
|
|
|
|
|
|
|
|
```
|
|
|
|
0000_0001 1001_0010
|
|
|
|
```
|
|
|
|
|
|
|
|
... the decoder will read the first byte and see that it doesn't have the high
|
|
|
|
order bit set, so it keep just the "1" for the value and shift 7 bits to the
|
|
|
|
left. Then the second byte is read; this one have the high order bit set, so
|
|
|
|
the remaining bits (in this case "001_0010") are added to the resulting value
|
|
|
|
and get `1001_0010` -- or 146.
|
|
|
|
|
|
|
|
Negative numbers are represented using 2's so if the decoder receives, for
|
|
|
|
example:
|
|
|
|
|
|
|
|
```
|
|
|
|
0000_0011 0111_1110 1110_1110
|
|
|
|
```
|
|
|
|
|
|
|
|
... which, when the high order bits are removed, it should generate "`1111_1111
|
|
|
|
0110_1110`", which is -146 (in 16 bits, just to make it shorter).
|
|
|
|
|
|
|
|
When an integer field is optional, the result must be decremented by 1. The
|
|
|
|
reason is that it should be something to differentiate both 0 and Null. So, an
|
|
|
|
optional integer with value 0 is, actually, Null; to get the value 0 for the
|
|
|
|
field, the incoming data will have value 1, which is decremented in 1 and goes
|
|
|
|
back to 0.
|
|
|
|
|
|
|
|
In the template, the fields appear as
|
|
|
|
|
|
|
|
- `<uInt32/>`: Unsigned Int of 32 bits.
|
|
|
|
- `<uInt64/>`: Unsigned Int of 64 bits.
|
|
|
|
- `<int32/>`: Signed Int of 32 bits.
|
|
|
|
- `<int64/>`: Signed Int of 64 bits.
|
|
|
|
|
|
|
|
### Types: Strings
|
|
|
|
|
|
|
|
ASCII strings are pretty simple to read: Again, the decoder keeps reading the
|
|
|
|
incoming data till you find a byte with the high order bit set (again, the stop
|
|
|
|
bit) and just convert to their respective ASCII character.
|
|
|
|
|
|
|
|
For example
|
|
|
|
|
|
|
|
```
|
|
|
|
0100_1000 0110_0101 0110_1100 0110_1100 1110_1111
|
|
|
|
```
|
|
|
|
|
|
|
|
Would generate the bytes 72, 101, 108, 108 and 111, which using the ASCII table
|
|
|
|
would result in "Hello". Note that the stop bit here represents "end of string"
|
|
|
|
and the bytes should not be grouped like in Ints.
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
So far, I didn't find any UTF8 strings, so I'm not quite sure how to process
|
|
|
|
them yet. Surely there is documentation around on how to read those, but since
|
|
|
|
this is my personal experience with the protocol, I decided to not mention it
|
|
|
|
here.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
Optional strings are Null when the first byte have a stop bit set and every
|
|
|
|
other bit is zero.
|
|
|
|
|
|
|
|
In the template, a string field appears as `<string>`.
|
|
|
|
|
|
|
|
### Types: Sequences
|
|
|
|
|
|
|
|
Sequences are basically arrays. The first field of a sequence is the "length"
|
|
|
|
(with the type "`<length>`" in the template) with the number of records
|
|
|
|
present. Inside the sequence, you have a list of field definitions, which may
|
|
|
|
even include more sequences.
|
|
|
|
|
|
|
|
Optional sequences affect the way the length is read: If optional, the length
|
|
|
|
should be treated as an optional Integer and thus the size is decremented by 1.
|
|
|
|
|
|
|
|
In the template, the sequence appears as `<sequence>`, with the length
|
|
|
|
following it. An example is
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<sequence name="Sequence">
|
|
|
|
<length name="NoSequence" id="123"/>
|
|
|
|
</sequence>
|
|
|
|
```
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
I describe most of the length fields with a name starting with "No". That's
|
|
|
|
because the FIX spec defines the lengths with that prefix.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
### Types: Decimals
|
|
|
|
|
|
|
|
Decimals are formed by two fields: Exponent and Mantissa. The way it works is
|
|
|
|
that if you have an Exponent of "-2" and a Mantissa of "1020", the resulting
|
|
|
|
value is `1020 * 10 ^ -2` ("1020 times 10 to the power of -2"), or "10.20".
|
|
|
|
|
|
|
|
Both Exponent and Mantissa are read as Signed Ints.
|
|
|
|
|
|
|
|
An Optional Decimal means the Exponent is optional. The documentation says that
|
|
|
|
the Mantissa is always mandatory, but there is a catch: If the Exponent is
|
|
|
|
null, then the Mantissa is not present and the whole Decimal is Null;
|
|
|
|
otherwise, the decoder is expected to read the Mantissa and the formula above
|
|
|
|
should be applied.
|
|
|
|
|
|
|
|
Also, because Exponent and Mantissa are two fields, they can have different
|
|
|
|
operators. I'll show some examples after the Operator, mostly because I've seen
|
|
|
|
both with different operators and they make a mess to read.
|
|
|
|
|
|
|
|
In the template, the decimal field appears as `<decimal>`, with the exponent
|
|
|
|
and mantissa as internal fields.
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<decimal name="ADecimal" id="123">
|
|
|
|
<exponent/>
|
|
|
|
<mantissa/>
|
|
|
|
</decimal>
|
|
|
|
```
|
|
|
|
|
|
|
|
### Type: Presence Map
|
|
|
|
|
|
|
|
Presence Maps are used in conjunction with operators. They are read like
|
|
|
|
unsigned Ints are read (read bytes till you find the one with the high order
|
|
|
|
bit, remove the high order bits and put all the bits in sequence) but do not
|
|
|
|
have any conversion in themselves. Every time the decoder need to check if a
|
|
|
|
field is present in the presence map, the bit is consumed and the line
|
|
|
|
moves on.
|
|
|
|
|
|
|
|
Presence Maps are not present in the template and their presence is implied if
|
|
|
|
there is at least one field that requires it. For example, if all the fields in
|
|
|
|
a sequence are mandatory, there will be no Presence Map in the incoming data.
|
|
|
|
|
|
|
|
The bits in the Presence Map are in the order of the fields in the template.
|
|
|
|
For example, if a template with:
|
|
|
|
|
|
|
|
1. A mandatory field;
|
|
|
|
2. A field with an operator that requires the presence map (I'll mention those
|
|
|
|
later);
|
|
|
|
3. Another mandatory field;
|
|
|
|
4. And, finally, another field with operator.
|
|
|
|
|
|
|
|
... it is possible to have a Presence Map as `1110_0000`, in which:
|
|
|
|
|
|
|
|
1. The first bit is the stop bit, so the decoder assumes this is the last byte
|
|
|
|
of the presence map.
|
|
|
|
2. The second bit indicates that the first field with operator is present. It
|
|
|
|
does *not* represent the mandatory field 'cause, well, it is mandatory and,
|
|
|
|
thus, is always present.
|
|
|
|
3. The second bit indicates the second field with an operator is present.
|
|
|
|
|
|
|
|
(Again, I'll mention which operators require the presence map.)
|
|
|
|
|
|
|
|
## Operators
|
|
|
|
|
|
|
|
Operators define a way to deal with some fields. I've seen 5 different types of
|
|
|
|
operators:
|
|
|
|
|
|
|
|
- No Operator;
|
|
|
|
- Constant;
|
|
|
|
- Default;
|
|
|
|
- Copy;
|
|
|
|
- Delta;
|
|
|
|
- Increment.
|
|
|
|
|
|
|
|
### Operator: No Operator
|
|
|
|
|
|
|
|
When there is no operator defined in the field definition in the template, then
|
|
|
|
the operator is the "no operator" operator. It means there is no special way of
|
|
|
|
dealing with the incoming value.
|
|
|
|
|
|
|
|
When a field have No Operator, there will be no bit in the Presence Map.
|
|
|
|
|
|
|
|
All the previous examples of the template have no operator.
|
|
|
|
|
|
|
|
### Operator: Constant
|
|
|
|
|
|
|
|
A field with the Constant operator will not appear in the incoming data and the
|
|
|
|
decoder should assume that its value is the value in the constant. Previously I
|
|
|
|
mentioned that a list of securities may have the field 22, "Source", and field
|
|
|
|
207, "Exchange", with constant values, so they would be defined as
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<string name="Source" id="22">
|
|
|
|
<constant value="123"/>
|
|
|
|
</string>
|
|
|
|
<string name="Exchange" id="207">
|
|
|
|
<constant value="EXCHANGE"/>
|
|
|
|
</string>
|
|
|
|
```
|
|
|
|
|
|
|
|
There is a catch, though: When a Constant field can be Null
|
|
|
|
(`presence="optional"`), then the decoder needs to use the Presence Map bit; if
|
|
|
|
it is set, the constant value should be used; if it is not set, then the field
|
|
|
|
value is Null.
|
|
|
|
|
|
|
|
The Presence Map should be use only if there is a field with a constant value
|
|
|
|
that is optional.
|
|
|
|
|
|
|
|
### Operator: Default
|
|
|
|
|
|
|
|
The Default operator is similar to the Constant operator, but if the bit for
|
|
|
|
the field is set in the Presence Map, then the value for the field should be
|
|
|
|
read in the incoming data; otherwise, the Default value should be used.
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
In a way, you can read this: Is the value present in the incoming data
|
|
|
|
(indicated in the Presence Map)? Then read the value in the incoming data;
|
|
|
|
otherwise, use the default value.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
Example
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<uInt32 name="Type" id="3">
|
|
|
|
<default value="1"/>
|
|
|
|
</uInt32>
|
|
|
|
```
|
|
|
|
|
|
|
|
### Operator: Copy
|
|
|
|
|
|
|
|
The copy operator indicates that the value for this record have the same value
|
|
|
|
of the previous record; if it is the first record, then the value should be
|
|
|
|
used. If the Presence Map bit is set for the field, then the decoder must read
|
|
|
|
the value in the incoming data; if it is not set, then the previous value should
|
|
|
|
be used.
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
In the data I saw, every first record have the bit set.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
An example: You can have a template like
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<string name="MDReqID" id="262">
|
|
|
|
<copy/>
|
|
|
|
</string>
|
|
|
|
```
|
|
|
|
|
|
|
|
... and the incoming data had the following records and their Presence Maps:
|
|
|
|
|
|
|
|
1. The first record have the bit set for this field in the Presence Map and the
|
|
|
|
strings reads "first". The result for this field in this record will be
|
|
|
|
the value "first".
|
|
|
|
2. The second record doesn't have the bit set in the Presence Map. So the
|
|
|
|
decoder reuses the previous value and this record will have the field with
|
|
|
|
the value "first" (again).
|
|
|
|
3. The third record have the bit set again, and the value "second". This is the
|
|
|
|
value for the field in this record.
|
|
|
|
4. The fourth record doesn't have the bit set and the decoder reuses the value
|
|
|
|
"second" for the field.
|
|
|
|
|
|
|
|
The Copy operator may have the initial value. For example
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<string name="MDReqID" id="262">
|
|
|
|
<copy value="string"/>
|
|
|
|
</string>
|
|
|
|
```
|
|
|
|
|
|
|
|
This means that you should use "string" as previous value, even in the first
|
|
|
|
record.
|
|
|
|
|
|
|
|
As pointed, fields with the Copy operator appear in the Presence Map.
|
|
|
|
|
|
|
|
### Operator: Delta
|
|
|
|
|
|
|
|
Delta is an operator similar to Copy, but instead of using the value of the
|
|
|
|
previous record in this field, the new value must be computed using the previous
|
|
|
|
value and the current one. Again, if there is no previous value, then there is
|
|
|
|
no operation to be done and the incoming value is the current one.
|
|
|
|
|
|
|
|
An example:
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<uInt32 name="NumberOfOrders" id="346">
|
|
|
|
<delta/>
|
|
|
|
</uInt32>
|
|
|
|
```
|
|
|
|
|
|
|
|
1. The first record comes with the value of "300". That's the value for the
|
|
|
|
field.
|
|
|
|
2. The second record comes with the value "2". That should be added in the
|
|
|
|
previous value and used, so the field for the second record is "302".
|
|
|
|
3. The third record comes with the value "3". Again, the previous value should
|
|
|
|
be used and the current one should be added. So the field for the third
|
|
|
|
record have the value "305".
|
|
|
|
|
|
|
|
Fields with the Delta operator do not appear in the Presence Map.
|
|
|
|
|
|
|
|
### Operator: Increment
|
|
|
|
|
|
|
|
Increment works like the Delta operator 'cause it always add a value to the
|
|
|
|
previous one, but the value to be added is always 1.
|
|
|
|
|
|
|
|
If the bit for the field is set in the Presence Map, the value for the field is
|
|
|
|
the one in the incoming data; otherwise, the value will be the previous value
|
|
|
|
added by 1.
|
|
|
|
|
|
|
|
Example:
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<uInt32 name="RptSeq" id="83">
|
|
|
|
<increment/>
|
|
|
|
</uInt32>
|
|
|
|
```
|
|
|
|
|
|
|
|
1. The first record have the bit set in the Presence Map, the decoder reads the
|
|
|
|
value "100". That's the field value for the record.
|
|
|
|
2. The second have doesn't have the bit set, so nothing should be read from the
|
|
|
|
incoming data, but the field value should be "101" for this record.
|
|
|
|
|
|
|
|
Fields with the Increment operator appear in the presence map.
|
|
|
|
|
|
|
|
## Presence Map Map
|
|
|
|
|
|
|
|
There is a simple map that indicates if a field appears or not in the Presence
|
|
|
|
Map, [according to JetTek](https://jettekfix.com/education/fix-fast-tutorial/):
|
|
|
|
|
|
|
|
<table>
|
|
|
|
<tr>
|
|
|
|
<th>Operator</th>
|
|
|
|
<th>Appears for Mandatory Fields?</th>
|
|
|
|
<th>Appears for Optional Fields?</th>
|
|
|
|
</tr>
|
|
|
|
<tr>
|
|
|
|
<td>No Operator</td>
|
|
|
|
<td>No.</td>
|
|
|
|
<td>No.</td>
|
|
|
|
</tr>
|
|
|
|
<tr>
|
|
|
|
<td>Constant</td>
|
|
|
|
<td>No, the Constant value should always be used.</td>
|
|
|
|
<td>Yes; if set, use the Constant value; otherwise the field value is Null.</td>
|
|
|
|
</tr>
|
|
|
|
<tr>
|
|
|
|
<td>Copy</td>
|
|
|
|
<td>Yes; if set, use the incoming value is the current value;
|
|
|
|
otherwise, use the previous value.</td>
|
|
|
|
<td>Yes; same as Mandatory fields, but the value can be Null (e.g., it
|
|
|
|
was read as 0 for Ints or a single Null byte for Strings.</td>
|
|
|
|
</tr>
|
|
|
|
<tr>
|
|
|
|
<td>Default</td>
|
|
|
|
<td>Yes; if set, read the value from the incoming data; otherwise, use
|
|
|
|
the default value.</td>
|
|
|
|
<td>Yes; same as Mandatory fields.</td>
|
|
|
|
</tr>
|
|
|
|
<tr>
|
|
|
|
<td>Delta</td>
|
|
|
|
<td>No; the value in the incoming data should always be added to the
|
|
|
|
previous one.</td>
|
|
|
|
<td>No; same as Mandatory fields.</td>
|
|
|
|
</tr>
|
|
|
|
<tr>
|
|
|
|
<td>Increment</td>
|
|
|
|
<td>Yes; if set, read the value from the incoming data; otherwise, add
|
|
|
|
1 to the previous value.</td>
|
|
|
|
<td>Yes; same as Mandatory fields.</td>
|
|
|
|
</tr>
|
|
|
|
</table>
|
|
|
|
|
|
|
|
# Template Versioning
|
|
|
|
|
|
|
|
I didn't mentioned this before, but now that I explained some things about the
|
|
|
|
types and some information about the template, I can point that the template
|
|
|
|
file allows multiple versions of the same message types.
|
|
|
|
|
|
|
|
For example
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<?xml version="1.0" encoding="UTF-8"?>
|
|
|
|
<templates xmlns="http://www.fixprotocol.org/ns/fast/td/1.1">
|
|
|
|
<template xmlns="http://www.fixprotocol.org/ns/fast/td/1.1" name="SomeRecordType" id="1">
|
|
|
|
<string name="MsgType" id="35">
|
|
|
|
<constant value="Z"/>
|
|
|
|
</string>
|
|
|
|
<string name="SomeField" id="1"/>
|
|
|
|
</template>
|
|
|
|
|
|
|
|
<template xmlns="http://www.fixprotocol.org/ns/fast/td/1.1" name="SomeRecordType" id="2">
|
|
|
|
<string name="MsgType" id="35">
|
|
|
|
<constant value="Z"/>
|
|
|
|
</string>
|
|
|
|
<string name="SomeField" id="1"/>
|
|
|
|
<string name="SomeOtherField" id="2">
|
|
|
|
<default value="A Value!"/>
|
|
|
|
</string>
|
|
|
|
</template>
|
|
|
|
</templates>
|
|
|
|
```
|
|
|
|
|
|
|
|
The first thing you may notice is that there are two templates defined, one
|
|
|
|
with ID "1" and another with ID "2". Both have the same name and the same
|
|
|
|
constant value in the same field ID, but the initial data in the incoming block
|
|
|
|
defines which one should be used.
|
|
|
|
|
|
|
|
The incoming data starts with a Presence Map. The first bit on this is the
|
|
|
|
"Template ID". With that Template ID, the decoder can find the list of fields
|
|
|
|
that should be processed. This Presence Map also contains the map for the
|
|
|
|
fields in the root sequence -- in our example, if the Template ID decodes to
|
|
|
|
"2", the other bit in the Presence Map is the indication of the
|
|
|
|
"SomeOtherField".
|
|
|
|
|
|
|
|
{% note() %}
|
|
|
|
So far, I didn't find any data that didn't had the bit set for the template ID,
|
|
|
|
so I'm not actually sure what would happen if the bit is unset.
|
|
|
|
{% end %}
|
|
|
|
|
|
|
|
# Anomalies
|
|
|
|
|
|
|
|
I call "anomaly" anything that I had to spent way too much time to understand.
|
|
|
|
|
|
|
|
## Decimals With Different Operators
|
|
|
|
|
|
|
|
This is one thing that made things pretty hard to grasp at first. For example:
|
|
|
|
|
|
|
|
```xml
|
|
|
|
<decimal name="MDEntryPX" id="270" presence="optional">
|
|
|
|
<exponent>
|
|
|
|
<default value="0"/>
|
|
|
|
</exponent>
|
|
|
|
<mantissa>
|
|
|
|
<delta/>
|
|
|
|
</mantissa>
|
|
|
|
</decimal>
|
|
|
|
```
|
|
|
|
|
|
|
|
That seems simple. But there are a lot of moving pieces here:
|
|
|
|
|
|
|
|
1. The `presence="optional"` in the decimal means that the `exponent` can be
|
|
|
|
Null and only that.
|
|
|
|
2. The Default operator in the Exponent means the decoder must check if the
|
|
|
|
Exponent have a value in the incoming data or should use the default value
|
|
|
|
of "0".
|
|
|
|
|
|
|
|
There is an issue here: If the Presence Map indicates that the value is
|
|
|
|
present and the read value is 0, because the field is optional, the decoder
|
|
|
|
should consider the Exponent Null and, thus, there is no Mantissa and
|
|
|
|
everything is Null.
|
|
|
|
3. The Delta operator in the Mantissa should be used applying the incoming
|
|
|
|
value to the previous one. But, if the Exponent is not in the presence map,
|
|
|
|
because it has a default value, that's its value and it shouldn't be read in
|
|
|
|
the incoming data and the read value is actually applied to the Mantissa.
|
|
|
|
|
|
|
|
Like this:
|
|
|
|
|
|
|
|
1. The first record have the field set in the Presence Map and it is read as
|
|
|
|
"-2"; that's the Exponent. The next value is "1020", which is the Mantissa,
|
|
|
|
so the whole decimal is "10.20";
|
|
|
|
2. The second record have the field set in the Presence Map and it is read as
|
|
|
|
"0". Because the decimal is optional, the exponent is optional, and because
|
|
|
|
0 is Null for optional fields, there is no Exponent, and the next value is
|
|
|
|
*not* the Mantissa. The value for the field in this record is Null.
|
|
|
|
3. The third record have the field not set in the Presence Map. Because
|
|
|
|
Exponent has a default value, it becomes "0", and the Mantissa should be read.
|
|
|
|
If the incoming data have the value "10", the decimal becomes "10" (or
|
|
|
|
"10.00", if we use the same decimal places everywhere).
|
|
|
|
|
|
|
|
A weird thing I saw was related to the way the exchange was ordering the
|
|
|
|
results. It had a sequence of sell and buy orders in which
|
|
|
|
|
|
|
|
1. The first record was the sell order, with an Exponent of "0" and a Mantissa
|
|
|
|
of "5410". That meant the value is "5410" (pretty straight).
|
|
|
|
2. The second record was the buy order. It had an Exponent of "-2" and the
|
|
|
|
Mantissa had an incoming value of "526604". With the Delta operador, that
|
|
|
|
gives the value of "532014", but because the Exponent is "-2", the actual
|
|
|
|
value is "5320.14".
|
|
|
|
3. The weird thing happened in the third record, which was again a sell order.
|
|
|
|
The value should be exactly the same as the first, but the exchange sent an
|
|
|
|
Exponent of "0" and a Mantissa of "−526604". With the delta, that would bring
|
|
|
|
the value back to "5410".
|
|
|
|
|
|
|
|
I found it weird that they kept jumping between two different Exponents instead
|
|
|
|
of using a single one, and at the time I had some issues with the delta math in
|
|
|
|
my code, so...
|
|
|
|
|
|
|
|
## Null Length Sequences
|
|
|
|
|
|
|
|
Another strange thing I saw was the optional sequence: In practice there is no
|
|
|
|
difference between a sequence with 0 elements and one which the length is Null
|
|
|
|
-- specially if you think the protocol is, basically, a FIX generator. I have
|
|
|
|
no idea why it wasn't standardized that lengths are mandatory and a value of 0
|
|
|
|
means there is no values on it instead of doing a dance around optional and
|
|
|
|
mandatory sequences.
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
### Changelog:
|
|
|
|
|
|
|
|
- 2022-01-10: First release.
|
|
|
|
- 2022-01-10: Added information about the template versioning.
|
|
|
|
- 2022-01-13: Added examples of the tags in the template for the field types
|
|
|
|
and examples for operators.
|